188宝金博页面版

  • 图案背景
  • 纯色背景
视图
标记
批注
批注本地保存成功,开通会员云端永久保存 去开通
买卖提

上传于:2016-12-09

粉丝量:292

Hello!everyone!


  • 相关
  • 目录
  • 笔记
  • 书签

188宝金博页面版:更多相关文档

  • (13)葡萄糖检测试剂盒――氧化酶法

    星级: 2 页

  • (1-3)- β-D-葡聚糖检测试剂盒,真菌检测试剂盒

    星级: 1 页

  • β-葡聚糖试剂盒B-636-01061

    星级: 2 页

  • β-葡聚糖试剂盒

    星级: 2 页

  • β-葡聚糖试剂盒

    星级: 1 页

  • 葡萄糖检测试剂盒

    星级: 5 页

  • 真菌葡聚糖检测试剂盒(动态浊度法)质控品说明书ef

    星级: 1 页

  • 真菌葡聚糖检测试剂盒(动态浊度法)质控品说明书

    星级: 1 页

  • 葡萄糖检测试剂盒

    星级: 2 页

  • 葡萄糖检测试剂盒(己糖激酶法)

    星级: 1 页

  • 真菌葡聚糖检测试剂盒(动态浊度法)质控品说明书

    星级: 2 页

暂无目录

点击鼠标右键菜单,创建目录

暂无笔记

选择文本,点击鼠标右键菜单,添加笔记

暂无书签

在左侧文档中,点击鼠标右键,添加书签

188宝金博页面版: 美国ACC 葡聚糖检测试剂盒

下载积分: 10000

内容提示: Glucatell ? Kit (1g3)- b - D -glucan DetectionGeneral Product DescriptionThe Glucatell kit is specif i c for detection of (1 g 3)- b - D -glucan. The assay is based upon a modif i cation of the Limulus Amebocyte Lysate (LAL) pathway. Glucatell reagent is processed to eliminate Factor C, and is therefore specif i c for (1 g 3)- b - D -glucan. The reagent does not react with other polysaccharides, including beta-glucans with different glycosidic linkages. Glucatell is a chromogenic reagent that may be used...

文档格式:PDF | 页数:1 | 浏览次数:102 | 上传日期:2016-12-09 08:54:03 | 文档星级:
Glucatell ® Kit (1g3)- b - D -glucan DetectionGeneral Product DescriptionThe Glucatell kit is specif i c for detection of (1 g 3)- b - D -glucan. The assay is based upon a modif i cation of the Limulus Amebocyte Lysate (LAL) pathway. Glucatell reagent is processed to eliminate Factor C, and is therefore specif i c for (1 g 3)- b - D -glucan. The reagent does not react with other polysaccharides, including beta-glucans with different glycosidic linkages. Glucatell is a chromogenic reagent that may be used to perform either kinetic or endpoint assays in microplate readers. The standard Glucatell test is read at 405–410 nm.SensitivityThe sensitivity for Glucatell assay is determined by the lowest standard concentration on the standard curve used for the assay. The maximum sensitivity for Glucatell is 3.125 pg/mL when used with a microplate reader.Sample to Glucatell RatioKinetic Assay: Reconstituted Glucatell reagent is used at a ratio of 1:4 and a volume of 100 µL/well (55 tests/vial).Endpoint Assay: Reconstituted Glucatell reagent is used at a ratio of 1:1 and a volume of 50 µL/well (55 tests/vial).Performing the TestKinetic Assay: The Glucatell/sample mixture is incubated at 37±1°C in a microplate reader equipped with a 405–410 nm fi lter. Software is used to construct the standard curve and calculate glucan concentrations.Endpoint Diazo Assay: The Glucatell/sample mixture is incubated at 37±1°C in a microplate heating block for the recommended time period. 50 µL each of the three diazo reagents are then added to the mixture which is then read at 540–550 nm. Software is used to construct the standard curve and calculate glucan concentrations.ReconstitutionGlucatell reagent can be reconstituted differently depending on the assay you use. For endpoint assays, use 2.8 mL of only Pyrosol reconstitution buffer. For kinetic assays, combine 2.8 mL each of Pyrosol and Reagent Grade Water.StabilityStore all reagents at 2–8°C in the dark. Once reconstituted, Glucatell reagent should be stored at 2–8°C and used within 2 hours. Alternatively, reconstituted Glucatell reagent can be frozen at -20°C for 20 days, thawed once and used. The diazo reagents should be used the day they are prepared.Product Applications• Analyzing fi nal products for (1 g 3)- b - D -glucan• Investigating LAL Out of Specif i cation results• Qualifying raw materials• Monitoring cellulosic fi lter extractables• Monitoring fungal fermentation processes• Analyzing fermentation and cell culture media • Monitoring airborne glucan burden PackagingThe Glucatell kit is available as either an endpoint or kinetic chromogenic assay for use in microplates at different sizes: 55 test kit or 110 test kit. The kit contains the Glucatell reagent, a (1 g 3)- b - D -glucan standard, buffer, glucan-free water, glucan-free microplates and diazo reagents (endpoint kit only). Accessory Products1. 250 µL Pipette tips (PPT25)2. 1000 µL Pipette tips (PPT10)3. Pyrotubes ® (TB013), 13 x 100 mm borosilicate glass dilution tubesGlucatell ® Kit#GT002 - - - - - - - - - - - - - - - - - - - - - - - Kinetic assays; 110 tests#GT003 - - - - - - - - - - - - - - - - - - - - - - - -With diazo reagents for endpoint assays; 55 tests#GT004 - - - - - - - - - - - - - - - - - - - - - - - - Kinetic assays; 55 testsResearch ProductsCorporate HeadquartersAssociates of Cape Cod, Inc.124 Bernard E. Saint Jean DriveEast Falmouth, MA 02536-4445T (508) 540–3444 • F (508) 540–8680Online: www.acciusa.comUK Off i ceAssociates of Cape Cod Int’l Inc.Deacon Park, Moorgate RoadKnowsley, Liverpool L33 7RX, United KingdomT (44) 151-547-7444 • F (44) 151-547-7400 Online: www.acciuk.co.ukGerman Off i ceAssociates of Cape Cod PYROQUANT DIAGNOSTIK GmbHOpelstrasse 14, 64546 Mörfelden-Walldorf, GermanyT (49) 61 05-96 10 0 • F (49) 61 05-96 10 15 Online: www.pyroquant.de13PN001443-13 Rev6Research Products

188宝金博页面版:关注我们

  • 新浪微博

关注188宝金博页面版公众号

188宝金博页面版
阅读
APP
阅读
返回
顶部
188宝金博页面版官网登录在线平台入口(2026已更新)—江苏协昌电子科技股份有限公司